SCS-104 Check-in Table Settings

Check-in Table IP Address

The optional SCS-CTM Check-in Table Manager software is used to backup

the records of supervised network accounts on up to 32 different SCS-

104 line cards. Use SCS-CTM to repopulate the list of supervised network

accounts when one SCS-104 or SCS-101 line card is replaced by another

SCS-104 or SCS-101. Additionally, the list of supervised network accounts used by an SCS-104 or SCS-101 on a

primary receiver can be mirrored by the SCS-CTM for use by an SCS-104 or SCS-1011 card on a second receiver.

Refer to the SCS-CTM User’s Guide (LT-0940).
Note: The list of supervised network accounts on an SCS-104 line card is automatically populated as each panel

sends its supervisory check-in message to the SCS-104 line card.

Enter the IP address for the computer where the SCS-CTM Check-in Table Manager software is installed. When no

SCS-CTM software is installed, leave the IP address set to 000.000.000.000.

Check-in Table Port

Enter the IP port

used to communicate Check-In Table messages to the SCS-CTM Check-in Table Manager program.

Valid range is 1 to 65,535. Default is 2005.

Check-in Table ID

Enter the table ID number to be used by the SCS-CTM Check-in Table Manager to identify the check-in table. Valid

range is 1 to 255. Default is 1.

Host Automation

The SCS-1R Host Automation programming section allows adjustments to optimize the SCS-1R performance with

the host automation computer.

Host Name

Enter a Host Name up to 16 characters.

Host Port Type

Select Serial to send messages to the host automation computer through the Host Output serial port. Select

Network to send messages through the network connection on the SCS-150 to the host automation computer.

Default is Serial.

Host IP Address

Enter the Host IP Address. This is the IP address of the host automation computer. The default value is

192.168.000.250.

Host Port

The Host Port identifies the port on the host automation computer. Valid range is 1 to 65,535. The default value

is 2001.

Protocol

Select TCP to communicate with the host automation computer over the network using TCP protocol. Select UDP

to communicate using UDP protocol. Default is TCP.