Scs-104 network settings – DMP Electronics Security Control Receiver SCS-1R User Manual
Page 36

SCS-1R Installation Guide
Digital Monitoring Products
31
OPERATOR’S GUIDE
Send ANI/DNIS Information
Select to enable the Automatic Number Identification (ANI) and Dialed Number Identification Service (DNIS)
information to be sent to the host automation computer. ANI sends the phone number that the panel is using to
call. DNIS sends information about the phone number the panel dialed. Default is disabled.
Send Caller ID Information
Select to enable the Caller ID information to be sent. Caller ID sends the phone number that the panel is using to
call. Default is disabled.
Echo Cancel Disable
Echo Cancellation is technology used by telephone companies to eliminate echo from voice telephone
transmissions. In some cases this technology can interfere with alarm signals. If you have problems with Echo
Cancellation interfering with your signals, select to turn off the echo cancellers.
SCS-104 Network Settings
Net Line Enable
Select to enable the network for the selected line card. Default is
selected.
S16 and S17 Always
When disabled, the S16 Panel Not Responding message is sent to
the automation computer for each supervised account that has
stopped sending check-in messages unless 50 S16 messages have
been generated for different accounts within one minute. This could
occur because the network has failed. Once this occurs, S72 Network
Trouble is sent and the receiver stops sending S16 messages to the
automation computer. The receiver sends S73 Network Restored and
will begin sending S16 messages after the receiver starts receiving check-in messages again.
When enabled, the S16 Panel Not Responding message is always sent to the automation computer for each
supervised account that has stopped sending check-in messages without regard to the number of accounts
generating S16 messages.
When enabled, the S17 Panel Response Restored message is sent to the automation computer each time a
supervised account checks in for the first time after installation. This also occurs at an account’s first check-in
after the receiver or SCS-104 is powered-up. Default is disabled.
Acknowledge Panel Substitution Message
When selected, the SCS-104 replies with an acknowledgment to messages sent by substituted panels. See the
Substitution Code section of the panel programming guide for the definition of a substituted panel. The SCS-104
generates only one S58 Alarm: Panel Substitution message to the host automation computer and receiver printer for
each substituted panel. Subsequent messages from substituted panels do not generate additional S58 messages.
When not selected, substituted panels are not sent acknowledgments for their messages. For each message
received from a substituted panel, an S58 Alarm: Panel Substitution message is sent to the host automation
computer and receiver printer.
Local IP Address
Enter the Local IP Address. This is the SCS-104 IP address. The Local IP Address must be unique and cannot be
duplicated. The default value is 192.168.000.250.
Local Port
The Local Port identifies the port used to communicate messages to and from the panel. Valid range is 1 to
65,535. The default value is 2001.
Gateway Address
Enter the local Gateway Address to exit your local network. The default value is 000.000.000.000.
Subnet Mask
Enter the local Subnet Mask assigned to the SCS-104. The default value is 255.255.255.000.
Passphrase
To enable encrypted communication, enter an 8 to 16-character Passphrase using alphanumeric character. This
Passphrase must be programmed into every panel reporting to the SCS-104 at the receiver. The SCS-104 installed
in the receiver must also be programmed with the same Passphrase. To clear the passphrase press any Select Key
and then press the COMMAND key.
The passphrase can include numbers 0-9, letters A-Z, and special characters of - (dash), . (period), * (asterisk), #
(number), and a space. If you leave the Passphrase blank, the SCS-104 communicates with XR500 Series panels,
but the data is not encrypted. The Passphrase is blank by default.
Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that every XR500
Series panel reporting to the SCS-104 at the receiver be individually reprogrammed with a new
passphrase.