SCS-1R Installation Guide

Digital Monitoring Products

29

OPERATOR’S GUIDE

Local IP Address

Enter the Local IP Address. This is the SCS-150 IP address used for Web Programming and Net Host Output. The

Local IP Address must be unique and cannot be duplicated. The default value is 192.168.000.250.

Local Port

The Local Port identifies the port used for the Net Host Output connections. If a setting change is required, enter

the new number. Valid range is 1 to 65,535. The default value is 2001.

Gateway Address

Enter the local Gateway Address. The Gateway Address is needed if subnets are divided in your network. The

default value is 000.000.000.000.

Subnet Mask

Enter the local SUBNET MASK assigned to the SCS-150. The default value is 255.255.255.000.

Web User Name

Enter a User Name for web programming access. This is the User Name entered to gain access to the programming

and can be up to 10 characters long. Default is “NEW”.

Web Password

Enter the password to use for web programming access. This is the password used to gain access to the programming

and can be up to 10 characters long. Default is “NEW”. If the password is forgotten, a new password can be entered

at the keypad only.

Print Operation

This section assigns the printing operation and the activity log baud rate.

Print Operation

Select the printer operation. Default is Always.

Print Operation

Function

Never

Suppresses all printing

Always

Prints all messages from the receiver

Primary Fail (Host Output)

Prints only when the communication to the primary host fails

Note: If Print Operation is set to Always or Primary Fail, ensure that a printer is connected to the printer port.

Activity Log Baud Rate

Select the baud rate for the Serial Printer port. Default is 1200. Select 300, 600, 1200, 2400, 4800, 9600, 19200, or

38400.