Scs-150 programming, Scs-150 membrane keypad programming, Programming menu – DMP Electronics Security Control Receiver SCS-1R User Manual
Page 26: Service code (xr500 series panels), Receiver options
SCS-1R Installation Guide
Digital Monitoring Products
21
OPERATOR’S GUIDE
SERVICE CODE
00000
NO DD LINES
No DD Lines
Displays for four seconds if no DD lines are programmed.
SCS-150 Programming
Programming of the SCS-150 can be performed using the following methods:
Programming Method
Requirements
SCS-1R Membrane Keypad SCS-1R membrane keypad
Browser
SCS-150 Version 103 or higher have the ability to be programmed using a standard browser.
Note: IP and Gateway addresses must be programmed at the SCS-1R membrane keypad to
allow access.
Remote Link
Remote Link version 1.47 or higher when using an SCS-150 Version 100 or 101 only.
SCS-150 Membrane Keypad Programming
Programming Menu
Allows entry to the programming menu for the SCS-1R using the keypad display.
MENU? NO YES
Menu?
Select YES to enter the programming code. Select NO to return to the Time Display.
ENTER CODE: 6653
Programming Code
Enter PROG (6653) to enter the Programming Menu.
Service Code (XR500 Series panels)
This option allows the entry of a 5-digit service authorization code used to authenticate service personnel before
allowing access to panel programming or performing any user operations.
SCS-1R MENU
SERVICE CODE
Service Code (XR500 Series panels)
Press any top row Select key to enter the Service Code. Press the COMMAND key to
advance to the next section of programming.
Range for the 5-digit code is 00000-65535. When this feature is enabled on an XR500
Series panel a service person is required to enter a valid service user code for system
programming access. Once the code is authenticated with the receiver, access to panel
programming is granted. If the code is not authenticated, access is denied.
The receiver cannot authenticate service personnel until a number is entered at this
option. Entering 00000 at the receiver disables this operation and panel access is
always granted.
Note: This panel operation is available to purchase for XR500 Series panels with version
108 or higher software. Refer to the Feature Upgrade section in the XR500 Series
Programming Guide (LT-0679) for additional information.
Receiver Options
This section assigns the company name and system number as well as the communication type for each SCS-1R
Receiver incoming line.
SCS-1R MENU
RECEIVER OPTIONS
Receiver Options
Press any top row Select key to display the company name and configure the system.
Press the COMMAND key to advance to the next section of programming.
COMPANY NAME
-
Company Name
Enter your company name using two lines, each line can have up to 16 characters.
Enter the first 16 characters and press the COMMAND key to accept.
Enter the second 16 characters and press the COMMAND key to accept.
RECEIVER SYSTEM
NUMBER: 1
Receiver System Number
The LCD displays the current receiver system number. Press any top row Select key,
then enter the system number, 0 through 9. The default System Number is 1. Press the
COMMAND key when finished.
Note: This identifier is used by the automation computer to distinguish between
multiple SCS-1R systems.
RECEIVER KEY
KEY:********
Receiver Key
The current Receiver Key displays. Press the COMMAND key to leave the Receiver key
the same and move to the next programming option. Press any top row Select key to
change the Receiver Key.
Note: This is an eight-character alphanumeric entry. This key is requested by panels
in the field when using remote programming from this receiver. Once entered this key
does not display and should never be changed. Record this number in the Important
information Sheet at the end of this document and store in a secure place.
COMPANY NAME 2
-