Keypad Options
KPD KPD
OPT DIAG STOP
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under KPD OPT. The display
changes to CURRENT KEYPAD ADDRESS: # #.
CURRENT KEYPAD
ADDRESS: 01
Current Keypad Address
The keypad must be set to keypad address 01. This is the default setting and should
not be changed.
KEYPAD MODE:
*SUP
UNSUP
Keypad Mode
The keypad can be set for either Supervised or Unsupervised operation. It is
recommended the setting be left at the default Supervised setting.
DEFAULT KEYPAD
MSG:
Default Keypad Message
Press COMMAND to scroll past this option. The keypad does not provide a
programmable Keypad Message.
ARM PANIC KEYS:
PN
EM F1
Arm Panic Keys
The Panic Keys should be disabled. They cannot be used on the membrane keypad. If
an asterisk appears next to one of the options, for example *PN, press the Select key
under the option with the asterisk to remove the asterisk and disable the panic key.
ACTIVATE ZONE 2
SHUNT: NO YES
Zone 2 Shunt
Leave this option set to NO.
ACTIVATE ZONE 3
EXIT: NO YES
Zone 3 Exit
Leave this option set to NO.
4 DIGIT ENTRY
CARDS: NO YES
Entry Cards
Leave this option set to NO.
ALL?: NO YES
DELAY: 2
All?
Leave this option set to NO.
Accessing Keypad Diagnostics
KPD KPD
OPT DIAG STOP
Keypad Diagnostics (KPD DIAG)
The Keypad Diagnostic option allows you to check the display segments and test
individual keys.
Press the Select key under KPD DIAG. The keypad lights all display segments and turns
off LEDs (Power, ACK, Message). A few seconds later the keypad turns the display
off and turns LEDs on. The keypad then alternates between these two states for
approximately two minutes. Press COMMAND at any time to continue.
PRESS KEY TO
TEST
Test Individual Keys
The display changes to PRESS KEY TO TEST. This option allows you to test each
membrane key to ensure it is operating properly. Press and hold each key for about
two seconds. The key number being held appears in the display. Verify the correct
number displays before testing the next key.
Exiting the Installer Options