Model scs-110 modem power supply card, Description, Installing the scs-110 – DMP Electronics Security Control Receiver SCS-1R User Manual
Page 17: Power monitor leds, Lcd membrane keypad trouble led, Ups trouble led, Ac trouble led, Installation
Digital Monitoring Products
SCS-1R Installation Guide
12
INSTALLATION
Model SCS-110 Modem Power Supply Card
Description
The SCS-110 provides power to a maximum of eight line cards. Power is supplied through the modem rack
backplane connectors without additional cabling. The SCS-110 also provides LCD and keypad connection, UPS
system status, and the 120 VAC input monitoring information to the SCS-1R Receiver.
Installing the SCS-110
Always remove power to the SCS-1R Receiver when installing or removing the SCS-110.
Slide the SCS-110 into the modem rack far left hand position, with the card puller up as shown below.
Plug the flat cable from the membrane keypad PCB onto the card edge connector at the bottom of the
SCS-110. The light brown (pin 1) wire of the flat cable connector must face up on the power supply
card.
Silence
UPS Brownout Input
PWR
PWR TRBL
AC TRBL
UPS TRBL
CRT TRBL
Power Monitor LEDs
The green LED labeled PWR lights when the power supply to the SCS-110 is working properly. The red LED labeled
PWR TRBL is controlled by the SCS-120 Multibus Power Supply Card and lights when there is a power problem on
the SCS-110. The red LED remains lit until the power problem is corrected. The alert tone on the SCS-110 Modem
Power Supply Card sounds during a power problem and is silenced by pressing the silence switch on the SCS-110.
LCD Membrane Keypad Trouble LED
The LCD Membrane Keypad trouble LED lights and the alert tone sounds when the LCD Membrane Keypad fails to
operate or the cable is unplugged. The alert tone is silenced by pressing the silence button on the SCS-110.
UPS Trouble LED
The UPS (Uninterrupted Power Supply) trouble LED lights and the alert tone sounds when the UPS Brownout Input
is opened. Connect this circuit to the brownout contacts on your UPS system (Refer to SCS-130 information). No
End-of-Line resistor is needed. Silence the alert tone by pressing the silence button on the SCS-110.
AC Trouble LED
The AC trouble LED lights and the alert tone sounds when AC power to the SCS-130 Transformer Card fails. Silence
the alert tone by pressing the silence button on the SCS-110.