beautypg.com

Model scs-110 modem power supply card, Description, Installing the scs-110 – DMP Electronics Security Control Receiver SCS-1R User Manual

Page 17: Power monitor leds, Lcd membrane keypad trouble led, Ups trouble led, Ac trouble led, Installation

background image

Digital Monitoring Products

SCS-1R Installation Guide

12

INSTALLATION

Model SCS-110 Modem Power Supply Card

Description

The SCS-110 provides power to a maximum of eight line cards. Power is supplied through the modem rack

backplane connectors without additional cabling. The SCS-110 also provides LCD and keypad connection, UPS

system status, and the 120 VAC input monitoring information to the SCS-1R Receiver.

Installing the SCS-110

Always remove power to the SCS-1R Receiver when installing or removing the SCS-110.

Slide the SCS-110 into the modem rack far left hand position, with the card puller up as shown below.

Plug the flat cable from the membrane keypad PCB onto the card edge connector at the bottom of the

SCS-110. The light brown (pin 1) wire of the flat cable connector must face up on the power supply

card.

Silence

UPS Brownout Input

PWR

PWR TRBL

AC TRBL

UPS TRBL

CRT TRBL

Power Monitor LEDs

The green LED labeled PWR lights when the power supply to the SCS-110 is working properly. The red LED labeled

PWR TRBL is controlled by the SCS-120 Multibus Power Supply Card and lights when there is a power problem on

the SCS-110. The red LED remains lit until the power problem is corrected. The alert tone on the SCS-110 Modem

Power Supply Card sounds during a power problem and is silenced by pressing the silence switch on the SCS-110.

LCD Membrane Keypad Trouble LED

The LCD Membrane Keypad trouble LED lights and the alert tone sounds when the LCD Membrane Keypad fails to

operate or the cable is unplugged. The alert tone is silenced by pressing the silence button on the SCS-110.

UPS Trouble LED

The UPS (Uninterrupted Power Supply) trouble LED lights and the alert tone sounds when the UPS Brownout Input

is opened. Connect this circuit to the brownout contacts on your UPS system (Refer to SCS-130 information). No

End-of-Line resistor is needed. Silence the alert tone by pressing the silence button on the SCS-110.

AC Trouble LED

The AC trouble LED lights and the alert tone sounds when AC power to the SCS-130 Transformer Card fails. Silence

the alert tone by pressing the silence button on the SCS-110.