Pilz PSS SB NOT, Basic license User Manual
Page 99

8-15
Modular Block System: Emergency Stop Circuits
Program:
Motor 1.1 :Segment 01
: L
A
1.16
.K-G1
K-M1.1 switches on if K-G1 is “1” and
: U
E
0.08
.M1.1_Start
start command (here E 0.08) is “1”.
: =
M
070.01 .K-M1.1_Start
: CAL SB 067
Motor 1.2 :Segment 02
: L
A
1.16
.K-G1
K-M1.2 switches on if K-G1 is “1” and
: U
E
0.09
.M1.2_Start
the start command (here E 0.09) is “1”.
: =
M
070.02 .K-M1.2_Start
: CAL SB 067
Group 1
:Segment 03
: L
M
072.01 .FG-M1.1
K-G1 can only switch on if K-M1.1 and
: U
M
072.02 .FG-M1.2
K-M1.2 are error-free.
: =
M
070.00 .K-M1.2_Start
SB 067
RFK_K4
B - SSNR
X - RFK1
X - RFK2
X - RSet
X - Ein
FG - X
K
- X
KB 008
E
0.01
.RFK-K-M1.1 -
E
0.01
.RFK-K-M1.1 -
E
0.31
.Reset
-
M 070.01 .K-M1.1_Start -
- M 072.01 .FG-M1.1
- A 1.17
.K-M1.1
SB 067
RFK_K4
B - SSNR
X - RFK1
X - RFK2
X - RSet
X - Ein
FG - X
K
- X
KB 009
E
0.02
.RFK-K-M1.2 -
E
0.02
.RFK-K-M1.2 -
E
0.31
.Reset
-
M 070.02 .K-M1.2_Start -
- M 072.02 .FG-M1.2
- A 1.18
.K-M1.2
- PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB HYD, Basic license PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license