Output parameters, Error messages – Pilz PSS SB NOT, Basic license User Manual
Page 49

Modular Block System: Emergency Stop Circuits
6-7
Output parameters
•
FG:
Enable flag bit
FG = 0:
Not enabled
FG = 1:
Function enabled when no errors are present
Error messages
Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of DB 015 (1st data block), until the fault has been fully dealt
with.
• Error messages in DB015
- Bit 09:
E-STOP button operated
Remedy: Check button, cable and input card, release E-STOP
button and reset (input parameter
EIN)
- Bit 14:
Reset button pressed constantly (i.e. stuck in)
Remedy: Check button, cable and input card, release E-STOP
button and reset again (input parameter
EIN)
- Bit 15:
E-STOP released, ready for reset.
Remedy: Press reset button (input parameter
EIN)
• Error messages on the CPU-display
- E 001:
Parameter error
SSNR does not lie within the limits of 1 ... 200
- E 002:
Parameter error
SSNR assigned more than once OR
DW1015 in DB015 was not incremented
- PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB HYD, Basic license PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license