MBS Basics
Modular Block System: Emergency Stop Circuits
Assignment of input and output parameters
Input and output parameters should be assigned in accordance with the
details given in the operating manual.
WARNING!
If several unused output parameters are connected to the same flag,
malfunctions may occur in the standard function blocks. If an unused
output has to be assigned a flag, make sure the output is assigned to a
flag that is not used anywhere else in the program.
Minimum scan time
Most of the timer functions required within the blocks are performed using
cycle counters. This means that almost all the timers are available for use
in applications.
INFORMATION
• If MBS blocks are used, a minimum scan time must always be
entered in the configurator. Empirical values should be used.
• If the error message F-20/06 (error category/error number) appears in
the CPU display, you must amend the minimum scan time appropriately.
This error message indicates that the minimum scan time has been
exceeded. The PSS must not be operated while this error message is
present.
SB070 and SB071 automatically enter the minimum scan time in DW1022
of the administration data blocks. In this way it is automatically available to
the MBS.
INFORMATION
Please note that the times are imprecise. The lack of precision on times is
due to the cyclical processing of the user program. It is determined by the
scan time of the respective user program.
The following is generally valid:
The greater the ratio of time value to scan time, the greater accuracy you
will have with the required times.
- PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB HYD, Basic license PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license