beautypg.com

Pilz PSS SB NOT, Basic license User Manual

Page 89

background image

8-5

Modular Block System: Emergency Stop Circuits

Program:

Insert the following additional commands at the end of OB101:
: A

DB015

: I

DW1015

: BE

KB 002

-

M 110.01 .RLO-1

-

E

0.01

.E-STOP

-

M 110.00 .RLO-0

-

M 110.01 .RLO-1

-

- M 70.00

.NA_FG

SB 060

NA_Kat_2

B - SSNR
X - EIN
X - S1_Ö
X - QAnf
X - QAut

FG - X