6-34
Modular Block System: Emergency Stop Circuits
Standard Function Blocks
SB070
Please note:
Entering excessively high time values for monitoring operations will reduce
the safety level of your machine.
If you are using type 2 ESPE/AOPD devices, a maximum value of 150 ms
may be entered for parameter
RBWS (EN 61 496-1).
• The number of cycles calculated is rounded down and transmitted to the
data words in administration data block DB 015.
• The SB must be called up once only when the PSS is started up
(e.g. in OB120).
Error messages
• None
Blocks required
• OB120
• DB015:
Administration data block
DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.
This manual is related to the following products:
- PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB HYD, Basic license PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license