beautypg.com

2 overview, Section 2, Overview – Pilz PIT m3.2p machine tools pictogram User Manual

Page 7: 2overview

background image

Overview

Operating Manual PIT m3.2p
1003176­EN­02

7

2

Overview

The operating mode selector switch may only be operated in conjunction with a transpon­
der key. 5 transponder keys are available, each with different authorisations.

Transponder key

24 V DC

Evaluation device

Safety control system

(e.g. PNOZ m1p) with

"1oon" evaluation

Higher-level

process control system

SOM1

SOM2

SOM3

SOM4
SOM5
Service

In n

In n+1

In n+2

In n+3

In n+4

A1

A2

IDo0 ... IDo3,

IDi0, IDi1

SIo0 ... SIo3

6

4

6

4

Fig.: Operating mode selector switch in an application (principle)