beautypg.com

Pilz PIT m3.2p machine tools pictogram User Manual

Page 26

background image

Function description

Operating Manual PIT m3.2p
1003176­EN­02

26

Configuration options via the DIP switch

DIP switch setting

Operating mode
currently selected

Assigned output

Behaviour after the transponder
key is removed

[1]: Default setting

4 3 2 1

On

Off

OM1

SOM1

}

Operating mode currently se­
lected is maintained

}

The assigned button is backlit.

}

The assigned output has a "1"
signal

OM2

SOM2

OM3

SOM3

OM4

SOM4

OM5

SOM5

}

Switch to OM1

}

Button 1 is backlit

}

SOM1 has a "1" signal

[2]

4 3 2 1

On

Off

OM1

SOM1

}

Operating mode currently se­
lected is maintained

}

OM1 … OM4: The assigned
button is backlit.
OM5: All 4 buttons flash.

}

The assigned output has a "1"
signal

OM2

SOM2

OM3

SOM3

OM4

SOM4

OM5

SOM5

[3]

4 3 2 1

On

Off

OM1

SOM1

}

Switch to OM1

}

Button 1 is backlit

}

SOM1 has a "1" signal

OM2

SOM2

OM3

SOM3

OM4

SOM4

OM5

SOM5

NOTICE

Make absolutely sure that only the DIP switch settings described above are
assessed as valid. With all other DIP switch settings, the device switches to
a "Device error" fault condition.