Configuration options via the DIP switch
DIP switch setting
Operating mode
currently selected
Assigned output
Behaviour after the transponder
key is removed
[1]: Default setting
4 3 2 1
On
Off
OM1
SOM1
}
Operating mode currently se
lected is maintained
}
The assigned button is backlit.
}
The assigned output has a "1"
signal
OM2
SOM2
OM3
SOM3
OM4
SOM4
OM5
SOM5
}
Switch to OM1
}
Button 1 is backlit
}
SOM1 has a "1" signal
[2]
4 3 2 1
On
Off
OM1
SOM1
}
Operating mode currently se
lected is maintained
}
OM1 … OM4: The assigned
button is backlit.
OM5: All 4 buttons flash.
}
The assigned output has a "1"
signal
OM2
SOM2
OM3
SOM3
OM4
SOM4
OM5
SOM5
[3]
4 3 2 1
On
Off
OM1
SOM1
}
Switch to OM1
}
Button 1 is backlit
}
SOM1 has a "1" signal
OM2
SOM2
OM3
SOM3
OM4
SOM4
OM5
SOM5
NOTICE
Make absolutely sure that only the DIP switch settings described above are
assessed as valid. With all other DIP switch settings, the device switches to
a "Device error" fault condition.