1 interface for status information, Interface for status information – Pilz PIT m3.2p machine tools pictogram User Manual
Page 16
Function description
Operating Manual PIT m3.2p
1003176EN02
16
4.1
Interface for status information
Various status information can be signalled via the interface for status information (see
). The status information can be evaluated through a control system.
The status information is subdivided into the following information classes:
}
Operator actions
–
Insert transponder key
–
Remove transponder key
–
Select operating mode
}
Messages (e.g. user error, fault)
NOTICE
When the operating mode is selected (SIo3 … SIo0 = 3h, 8h ... Bh) and in
the event of a device error (Dh), the information remains present indefin
itely. All other information stays active for just 200 ms. After that time the
selected operating mode is again displayed.
Status information
Information class
SIo3
(MSB)
SIo2
SIo1
SIo0
(LSB)
Value
(in
Hex)
Reserved
0
0
0
0
0h
Reserved
0
0
0
1
1h
Transponder key 5 – Inserted [1]
Operator action
0
0
1
0
2h
OM5 selected
Operator action
0
0
1
1
3h
Transponder key 1 – Inserted [1]
Operator action
0
1
0
0
4h
Transponder key 2 – Inserted [1]
Operator action
0
1
0
1
5h
Transponder key 3 – Inserted [1]
Operator action
0
1
1
0
6h
Transponder key 4 – Inserted [1]
Operator action
0
1
1
1
7h
OM1 selected
Operator action
1
0
0
0
8h
OM2 selected
Operator action
1
0
0
1
9h
OM3 selected
Operator action
1
0
1
0
Ah
OM4 selected
Operator action
1
0
1
1
Bh
No authorisation [2]
User error
1
1
0
0
Ch
Device error [3]
Error
1
1
0
1
Dh
Button operated incorrectly [4]
User error
1
1
1
0
Eh
Transponder key removed
Operator action
1
1
1
1
Fh