background image

Function description

Operating Manual PIT m3.2p
1003176­EN­02

16

4.1

Interface for status information

Various status information can be signalled via the interface for status information (see

Block diagram [

 14]

). The status information can be evaluated through a control system.

The status information is subdivided into the following information classes:

}

Operator actions

Insert transponder key

Remove transponder key

Select operating mode

}

Messages (e.g. user error, fault)

NOTICE

When the operating mode is selected (SIo3 … SIo0 = 3h, 8h ... Bh) and in
the event of a device error (Dh), the information remains present indefin­
itely. All other information stays active for just 200 ms. After that time the
selected operating mode is again displayed.

Status information

Information class

SIo3
(MSB)

SIo2

SIo1

SIo0 
(LSB)

Value 
(in
Hex)

Reserved

­ ­ ­

0

0

0

0

0h

Reserved

­ ­ ­

0

0

0

1

1h

Transponder key 5 – Inserted [1]

Operator action

0

0

1

0

2h

OM5 selected

Operator action

0

0

1

1

3h

Transponder key 1 – Inserted [1]

Operator action

0

1

0

0

4h

Transponder key 2 – Inserted [1]

Operator action

0

1

0

1

5h

Transponder key 3 – Inserted [1]

Operator action

0

1

1

0

6h

Transponder key 4 – Inserted [1]

Operator action

0

1

1

1

7h

OM1 selected

Operator action

1

0

0

0

8h

OM2 selected

Operator action

1

0

0

1

9h

OM3 selected

Operator action

1

0

1

0

Ah

OM4 selected

Operator action

1

0

1

1

Bh

No authorisation [2]

User error

1

1

0

0

Ch

Device error [3]

Error

1

1

0

1

Dh

Button operated incorrectly [4]

User error

1

1

1

0

Eh

Transponder key removed

Operator action

1

1

1

1

Fh

This manual is related to the following products: