Function description
Operating Manual PIT m3.2p
1003176EN02
17
[1] When a button is released, information as to which transponder key is used will be dis
played for 200 ms (see Status information 2h and 4h … 7h). The selected operating mode
is then displayed (see Status information 3h and 8h … Bh).
Timing diagrams for operator actions [
[2] The fault "No authorisation" (Ch) is registered in the following cases:
}
Operating mode selected without transponder key
}
Operating mode selected with a transponder key that is not authorised for the selected
operating mode
}
Transponder key is not authorised for the active operating mode
}
Transponder key is not inserted in time before the operating mode is selected
Timing diagrams for user error: "No authorisation" [
.
[3] "Device error" (Dh) is signalled in the event of an internal device error.
Remedy:
}
Switch supply voltage off and then on again
}
Change the unit
Timing diagram for device error [
[4] The fault "Button operated incorrectly" (Eh) is displayed in the following cases:
}
Multiple operation of buttons
}
Button operated for too long (timeout for OM1 to OM4 = 5 s and timeout for OM5 = 10
s)
Note: If a key is operated for < 50 ms this will not be evaluated, so there will be no re
action.
}
Button was released after the transponder key was removed
Timing diagrams for user error: "Button operated incorrectly" [
.