3 monitoring of operating time, 4 switchover delay t1, Monitoring of operating time – Pilz PIT m3.2p machine tools pictogram User Manual
Page 50: Switchover delay t1

Operation
Operating Manual PIT m3.2p
1003176EN02
50
7.3
Monitoring of operating time
The switch to a different operating mode is only recognised once the corresponding button
has been operated for a defined period.
Button's operating time
Button
Operating mode
Output
Operating time
1
OM1
SOM1
> 50 ms and
< 5 s
2
OM2
SOM2
3
OM3
SOM3
4
OM4
SOM4
1
OM5 (Service)
SOM5
> 5 s and
< 10 s
7.4
Switchover delay t1
Once a button has been released, the assigned output on the operating mode interface
switches to a "1" signal after the switchover delay t1 has elapsed (see
). This defined switchover delay guarantees that only one operating mode at a
time has a "1" signal at the assigned output.
SOM1
SOM2
SOM3
SOM4
SOM5
t1
t1
Fig.: Time behaviour when switching operating mode
This manual is related to the following products: