7.6.3

Status information via authorisation display

If a transponder key is inserted in the slot of the operating mode selector switch, its author­

isations are displayed via the authorisation display LEDs (see 

Control elements [

 10]

).

Evaluation of LED signals

Legend:

LED on

LED off

LED

Status

Meaning

All LEDs

}

No transponder key connected or

}

Authorisation not recognised, or not recognised
fully

Authorisation available for OM1 ... OM5

LED "1"

No authorisation for OM1

Authorisation available for OM1

LED "2"

No authorisation for OM2

Authorisation available for OM2

LED "3"

No authorisation for OM3

Authorisation available for OM3

LED "4"

No authorisation for OM4

Authorisation available for OM4

LED "5"

No authorisation for OM5

Authorisation available for OM5