Wiring

Operating Manual PIT m3.2p
1003176­EN­02

43

Functional earth

6.2

Connecting the unit

Proceed as follows:

1. Connecting the supply voltage

a Connect the supply voltage to (A1, A2).

Please note the following: 
The power supply must meet the regulations for extra low voltages with protective
separation (SELV, PELV). 
The cables for the unit's supply voltage (A1, A2) must be fitted with a 4 A fuse,
characteristic B/C.

2. Connecting the operating mode interface's semiconductor outputs

a Connect the operating mode interface's semiconductor outputs to a control system

that supports "1ooN" evaluation. 
You must read the information concerning intended use (see 

Intended use [

12]

).

3. Connecting the interface's terminals for status information

a Connect the terminals (SIo0 ... SIo3) to a control system that supports the evalu­

ation of status information.

4. Configure communication mode for downloading the Key ID number

a To download the Key ID number in handshake­controlled communication mode,

connect terminals IDo3 and IDi1 of the Key ID interface.
No configuration is required for transmitter­controlled communication mode.

5. Connecting the terminals of the Key ID interface

a Depending on the selected communication mode, connect the terminals of the Key

ID interface to a control system that supports the download of the Key ID number.

or

a Connect IDo0 to a control system, if all you wish to do in handshake­controlled

communication mode is evaluate whether the transponder key is valid/invalid. In
this case you will only use IDo0 as a signal output. The unused terminals on the
Key ID interface (IDo1, IDo2 and IDi0) may remain unwired ("open").

This manual is related to the following products: