Wiring
Operating Manual PIT m3.2p
1003176EN02
43
Functional earth
6.2
Connecting the unit
Proceed as follows:
1. Connecting the supply voltage
a Connect the supply voltage to (A1, A2).
Please note the following:
The power supply must meet the regulations for extra low voltages with protective
separation (SELV, PELV).
The cables for the unit's supply voltage (A1, A2) must be fitted with a 4 A fuse,
characteristic B/C.
2. Connecting the operating mode interface's semiconductor outputs
a Connect the operating mode interface's semiconductor outputs to a control system
that supports "1ooN" evaluation.
You must read the information concerning intended use (see
).
3. Connecting the interface's terminals for status information
a Connect the terminals (SIo0 ... SIo3) to a control system that supports the evalu
ation of status information.
4. Configure communication mode for downloading the Key ID number
a To download the Key ID number in handshakecontrolled communication mode,
connect terminals IDo3 and IDi1 of the Key ID interface.
No configuration is required for transmittercontrolled communication mode.
5. Connecting the terminals of the Key ID interface
a Depending on the selected communication mode, connect the terminals of the Key
ID interface to a control system that supports the download of the Key ID number.
or
a Connect IDo0 to a control system, if all you wish to do in handshakecontrolled
communication mode is evaluate whether the transponder key is valid/invalid. In
this case you will only use IDo0 as a signal output. The unused terminals on the
Key ID interface (IDo1, IDo2 and IDi0) may remain unwired ("open").