Wiring

Operating Manual PSSu E F INC(­T)
1001454­EN­07

27

6

Wiring

6.1

General wiring guidelines

Please note:

}

The module's connections are galvanically isolated from the module supply and peri­
phery supply.

}

For EMC reasons we recommend that you operate inputs A, B, C exclusively as differ­
ential inputs with inverted signals (A+/A­, B+/B­, C+/C­).

}

The module evaluates open differential inputs (A+/A­, B+/B­, C+/C­) as a 1 signal.

}

The module evaluates open function inputs (G, L, S) as a 0 signal.

}

Use twisted pair cables to carry the inverted signals. This will increase the noise im­
munity.

}

Use shielded signal cables with metallic plugs.

}

On base modules with C­rail:

Connect the shield to the terminals on the C­rail.

Connect the C­rail with low impedance to the functional earth.

}

On base modules without C­rail:

Connect the shield as shown in the terminal configuration section.

The module connects the shield to the functional earth via the mounting rail.

}

The channel for the incremental encoder's zero pulse has a different designation de­
pending on the manufacturer (N, C, Z, 0,...)

}

The supply voltages must be extra low voltages with protective electrical separation
(PELV or SELV) in accordance with VDE 0100, Part 410.

}

Use copper wiring.

}

Connect the two sensors via separate cables. This also applies to compact encoders.

}

The terminal configuration as stated on the front plate applies for base modules with C­
rail. The terminal configuration as stated in the technical documentation applies for all
other base modules.

6.1.1

Mechanical connection of the base modules

Procedure:

}

Use a flat blade screwdriver (DIN 5264­A)!

DIN 5264-A