23

8.1

Safety characteristic data

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

Monitoring 1
encoder

PL d

Cat. 2

SIL CL 2

1,80E­08

SIL 2

1,58E­03

20

Monitoring 2
encoder

PL e

Cat. 3

SIL CL 3

1,01E­09

SIL 3

8,41E­05

20

Monitoring
safe en­
coder

PL e

Cat. 4

SIL CL 3

2,35E­09

SIL 3

2,04E­04

20

PL e

Cat. 4

SIL CL 3

3,37E­10

SIL 3

2,88E­05

20

All the units used within a safety function must be considered when calculating the safety
characteristic data.

INFORMATION

A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.