Overview

2.1

Range

}

Base unit PNOZ m B0

}

Terminator

}

Documentation on data medium

2.2

Unit features

Using the product PNOZ m B0:

Base unit of the configurable control system PNOZmulti 2

The product has the following features:

}

Can be configured in the PNOZmulti Configurator

}

Semiconductor outputs:

4 safety outputs 
Depending on the application, up to PL e of EN ISO 13849­1 and up to SIL CL 3 of EN
IEC 62061

}

12 inputs for connecting, for example:

Emergency stop pushbuttons

Two­hand pushbuttons

Safety gate limit switches

Reset buttons

Light beam devices

Scanners

Enabling switches

PSEN

Operating mode selector switches

}

8 configurable inputs/outputs

Can be configured as:

Inputs (see above for connection options)

or

Auxiliary outputs

}

4 configurable outputs

Can be configured as:

Auxiliary outputs

or

Test pulse outputs

}

LED for:

Error messages

Diagnostics