Safe monitoring with "reduced speed" operating mode

Configuration in the PNOZmulti Configurator

Standstill: depending on requirement

Speed n1: reduced speed, depending on requirement

speed n2: greater than the maximum permitted speed.

If the "Overspeed" output (see red marking) = "0", either the maximum

permitted speed has been exceeded or the speed monitor has recog-

nised a fault.

"Overspeed" output = "0" must lead to the shutdown of the relevant ax-

is, irrespective of whether the "reduced speed" operating mode is ac-