6.2

Preparing for operation

6

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-4

6.2.2.2

Connect incremental encoder to the speed monitor via an adapter

Connect incremental encoder to the speed monitor via an adapter

6-

Drehzahlwaechter_Betriebsb_Inkremen_ueber_Adapt_HTL_BA

The adapter (e.g. PNOZ msi6p) is connected between the incremental

encoder and the drive. The output on the adapter is connected to the

RJ-45 female connector on the speed monitor.

The adapter can also be used without connecting to a drive.

The signals relevant for the speed monitor are utilised in parallel by

the adapter. The information stated in section 6.2.2.1 and in the

adapter operating manual must be observed when connecting the

supply voltage.

Supply voltage (12 V – 30 V) to incremental encoder only.

HTL signals may not be fitted with a terminating resistor.

Fig. 6-4:

Connection via adapter and drive

Incremental

encoder

A

/A

B

/B

X12

X22

Speed monitor

Drive

Adapter

24 V

0 V

24 V DC

0 V