2.1

Unit structure

2

Overview

2

2000

Overview

Overview

2-

2.1

Unit structure

2100

Unit structure

2-

2.1.1

Scope of delivery

Scope of delivery

2-

Lieferumfang_Abschl_779 110_Basis_BA

`

Base unit PNOZ m0p

`

Terminator 779 110

2.1.2

Unit features

Unit features

2-

Gerätemerkmale_Verwendung

Using the product PNOZ m0p:

Verwendung/Bildunterschrift_multi_Basis

Base units from the PNOZmulti modular safety system

Geraetemerkmale_Zusatz BA Einleitung

The product has the following features:

Gertemerkmale PNOZ m0p

`

Can be configured in the PNOZmulti Configurator

`

Positive-guided relay outputs:

– 2 safety outputs

Depending on the application, up to PL e of EN ISO 13849-1 and

up to SIL CL 3 of EN IEC 62061

`

Semiconductor outputs:

– 4 safety outputs

Depending on the application, up to PL e of EN ISO 13849-1 and

up to SIL CL 3 of EN IEC 62061

– 1 auxiliary output

`

4 test pulse outputs

`

1 cascading input and output; can also be used as a standard output

`

20 inputs for connecting:

– E-STOP pushbuttons

– Two-hand buttons

– Safety gate limit switches

– Reset buttons

– Light beam devices

– Scanners

– Enabling switches

– PSEN

– Operating mode selector switches

– Pressure sensitive mats

`

Integrated interface:

– PNOZ m0p: Serial interface RS 232

– PNOZ m0p ETH: Ethernet interface

`

Muting function

`

Connectable:

– 1 fieldbus module on the left

– 4 expansion modules on the left