Anschlussbeispiel_Verbindungsmodul_Reihenschalitung_5_Basisgeräte_Text

The reaction times are calculated in the same way as application exam-

ple 1. After pressing S1 on Base 1, the semiconductor outputs switch

after the following reaction times t

SUM

:

O0 on Base 2: 69 ms

O1 on Base 3: 104 ms

O0 on Base 4: 139 ms

O0 on Base 5: 104 ms

_Dummy-Vorlage

I3 I6

Base 1

Base 2

Base 3

S1

K3

Base 4

Base 5

I4 I6

K2

O0

O1

K4

O0

K5