Appendix a - specifications/dimensions – StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual
Page 97

84
Appendix A - Specifications/Dimensions
StorCase Technology, Inc.
InfoStation 16-Bay RAID User's Guide - Rev. F00
The following InfoStation specifications and dimensions are provided for reference only.
Appendix A - Specifications/Dimensions
Physical
Specifications
Rack Mount
Height
5.17" (131.3mm)
Width
17.5" (444.5mm)
Depth
22.63" (574.8mm)
(1)
Environmental Specifications
Operating
Storage
Ambient Temperature
0° C to 35° C
-40° C to 70° C
Relative Humidity
(1)
10% to 80%
10% to 90%
Altitude
-1000 to 10,000 ft
-1000 to 40,000 ft
-305m to 3048m
-305m to 12195m
Shock
(2)
10g
60g
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
Weight
60.0 lbs (27.3kg)
Weight of empty chassis (no drives installed)
Electrical
Specifications
(per 460W Power Supply Module)
AC Input
DC Output
Chassis Reliability/Maintainability
MTBF
100,000 Hours
Preventive
Maintenance
Power Supply Module
100 to 240 VAC, 50/60Hz, 8-4A
5V at 26A, 12V at 28A
Fan Module
160 CFM
Cooling
(per Fan
Module)
(1)