StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual
Page 68

InfoStation 16-Bay RAID User's Guide - Rev. F00
StorCase Technology, Inc.
RAID Controller Configuration
55
RAID Params Menu
1.1 Array 1
This function enables the user to configure/reconfigure Array 1.
1.1.1 Array 1 Reconfigure RAID
CAUTION:
Data lost during reconfiguration cannot be recovered! StorCase strongly
recommends the user to backup all data before reconfiguring.
NOTE:
To avoid accidental erasure of existing RAID configurations, Yes must be
selected prior to saving any new RAID configurations.
Select either No or Yes.
1.1.2 RAID Level
NOTE:
To remove an existing RAID level, reconfigure the array with RAID level None.
Select either 0, 1, 0+1, 3, 5, 30, 50, or None.
1.1.3 Disk Number
NOTES:
Verify that the required number of disks for all arrays are connected before
configuring an array. Refer to Table 3 for further information.
The number of disks in the array does not include the "hot spare" disk.
Select the number of disks in the RAID.