beautypg.com

StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual

Page 75

background image

62

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 16-Bay RAID User's Guide - Rev. F00

2.1.3 Set Connection Mode

Select either Arbitration Loop (default) or Point-to-Point.

2.1.4 Set Data Rate

Select either 1 Gbit, 2 Gbit, or Auto-Negotiated (default).

2.1.5 LUN Map

Select a LUN (0-15) and a corresponding slice to map to.

2.2 Secondary FC

This function enables the user to configure Secondary FC settings for use in multiple host
applications. Submenus are the same as 2.1 Primary FC.

2.3 SAN Mask

SAN Masking (also known as LUN Masking) is a differentiation tool for use on fibre networks
based on the unique Worldwide Name (WWN) of each fibre card. This function enables the
user to specify which hosts are able to see the RAID controller.

2.3.1 Visible for All Hosts

This function enables the user to select whether or not the RAID controller is visible to
connected hosts.

2.3.1.1 Port 1

Select either Enable or Disable. Enable allows hosts connected to Port 1 to view the RAID
controller.

2.3.1.2 Port 2

Select either Enable or Disable. Enable allows hosts connected to Port 2 to view the RAID
controller.

This manual is related to the following products: