98

Appendix C - Troubleshooting

StorCase Technology, Inc.

InfoStation 16-Bay RAID User's Guide - Rev. F00

Operation Problems

Invalid NVRAM message appears.

Cause - NVRAM error or malfunction.

Fix -

Save settings and restart controller. Contact StorCase Technical Support if the
problem persists.

Data loss in Windows 2000 during system shutdown.

Cause - Some data was still in cache buffer during system shutdown.

Fix -

Set Cache Off. To shutdown, select Restart System and wait for 30 seconds before
powering off. Shutdown host OS after shutting down controller.

Remote Terminal Problems

Unable to access the Configuration Mode using the remote terminal (Monitor

Utility).

Cause - The terminal communication settings might not match the settings of the RAID

Controller.

Fix -

Verify that the terminal communication settings of the remote terminal and the RAID
Controller match. Default settings for the RS-232 port is 19200 Baud, 8 Data Bits,
1 Stop Bit, and NO Parity.