RAID Controller Configuration

51

5.

Press four times to return to the Main Menu.

6.

Arrow down and select NVRAM. Press .

7.

Select Update NVRAM and press .

Select Yes and press .

8.

Select Restart and press .

Select Yes and press .

9.

Controller will now reboot (LUN will be mapped upon reboot).

10. To verify LUN Mapping settings, select RAID FUNCS from the Main Menu and press

.

11.

Select Statistics and press .

12. to highlight the Output (right) side of the HyperTerminal screen. Use the

keys to scroll through Output to view either the “Primary SCSI Channel” or

“Secondary SCSI Channel” (depending where the LUNs were mapped to).

13. If the LUN settings were successfully applied, you should see the array number

and slice numbers listed in the LUN Map section (Figure 23).