beautypg.com

Rear panel – StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual

Page 19

background image

6

Introduction

StorCase Technology, Inc.

InfoStation 16-Bay RAID User's Guide - Rev. F00

Rear Panel

(Figures 3A & 3B)

WARNING:

DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These handles are
specifically designed for the installation and removal of modules only!

NOTE:

Blank plate (provided) must be installed if any module slot is left empty. Instal-
lation of the blank plate is necessary for proper cooling inside chassis.

RAID Controller Module - Provides two (2) DB9 connectors for RS-232 and
Modem and one (1) RS-232 serial port for InfoStation external monitoring and
configuration (via InfoMon).

SCSI-to-SATA versions also provide either two (2) VHDCI I/Os for dual SCSI Host
channels or four (4) VHDCI I/Os for daisy-chaining applications.

FC-to-SATA versions also provide two (2) FC ports for dual FC-ALs or four (4) FC
Ports for daisy-chaining applications.

Refer to section "RAID Controller Module Panel" for further information.

Power Supply Module(s) - Two (2) 460W redundant, hot swappable power
supply modules. Each module features overvoltage and overcurrent protection, total
usage hours, and power supply fault detection.

Module LED(s) -

Green LED -

Steady glow indicates normal power supply operation.
No glow indicates no A/C power.

Red LED -

Steady glow indicates either:

Power supply failure.

or

A/C cord is plugged in, but power switch is in the OFF position.

Power Switch(es) - Rocker switch(es) control power to the power supply
module(s).

A/C Power In - Accepts U.S. and other available international standard power
cables.

Fan Module(s) - Two (2) redundant, hot swappable fan modules. Each module
contains two (2) high-pressure, variable-speed fans for ample chassis cooling (160
CFM per module).