66
RAID Controller Configuration
StorCase Technology, Inc.
InfoStation 16-Bay RAID User's Guide - Rev. F00
Terminal Port Menu
NOTES:
The RAID controller's terminal port settings must match the settings of the re-
mote terminal on the host.
Flow control should be set to "NONE" on the host terminal (refer to section
"RAID Management Connection Setup" and Table 1 for further information).
3.2 Terminal Port
This function enables the user to set the Baud Rate, Stop Bit, Data Bit, and Parity parameters
for the terminal port to match those of the host.
3.2.1 Baud Rate
Select either 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, or 115200 (default).
3.2.2 Stop Bit
Select either 1 (default) or 2.
3.2.3 Data Bit
Select either 7 or 8 (default).
3.2.4 Parity
Select either None (default), Odd, or Even.