StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual
Page 94

InfoStation 16-Bay RAID User's Guide - Rev. F00
StorCase Technology, Inc.
RAID Controller Configuration
81
6.A.4.1 Test Disk SMART
This function enables the user to check if a disk supports SMART and the current status of
one disk or all disks.
6.A.4.2 SMART Mode
Select Disable to disable the SMART function for all disks.
Select Enable (Alert only) to enable the controller to check status of all disks. An audible
alarm will sound in the event of a SMART warning.
Select Enable (Permanent Clone) to enable controller to select one spare disk and one clone
disk in the event of a SMART warning. Once disk cloning is done, the source disk will remain
in a state of mirroring without replacement.
If there is no spare disk, disk cloning will not occur.
Select Enable (Start Swap after Clone) to enable controller to select one spare disk and
one clone disk in the event of a SMART warning. Once disk cloning is done, the source disk
will remain in a state of mirroring with replacement.
If there is no spare disk, disk cloning will not occur.
6.A.4.3 SMART Check Time
Select the desired length of time (60 min/30 min/15 min/1 min) needed to execute the SMART
function.
6.A.4.4 Bad Blocks
6.A.4.4.1 View Statistics
This function enables the user to view disk status.