InfoStation 16-Bay RAID User's Guide - Rev. F00

StorCase Technology, Inc.

RAID Controller Configuration

63

2.3.2 SAN Mapping

This function enables the user to map individual LUNs to a specified host, thereby limiting
access to certain slices to single hosts (even in dual host confgurations).

2.3.2.1 Port 1

Hit Enter to proceed to 2.3.2.1.1 - 2.3.2.1.8 Select Host.

2.3.2.1.1 - 2.3.2.1.8 Select Host

Select Host 1 - Host 8, then select LUN (0-7). Select Yes or No to confirm selection.

2.3.2.2 Port 2

Hit Enter to proceed to 2.3.2.2.1 - 2.3.2.2.8 Select Host.

2.3.2.2.1 - 2.3.2.2.8 Select Host

Select Host 1 - Host 8, then select LUN (0-7). Select Yes or No to confirm selection.

2.3.3 Edit WWN Table

This function enables the user to enter individual host WWNs to the RAID controller.

2.3.3.1 - 2.3.3.8 Select Host

Select Host 1 - Host 8 and enter WWN value (default = 0000000000000000).

2.3.4 View WWN Table

This function enables the user to view a list of host WWNs in the Monitor Utility (cannot be
viewed from the control panel).