Controller Module

11

InfoStation 16-Bay RAID User's Guide - Rev. F00

StorCase Technology, Inc.

FC-to-SATA
(S10K112)

Figure 4D: RAID Module Controller Panel

(FC-to-SATA)

Modem

Port

RS-232

Serial Port

(DB9)

RS-232

Serial Port

(Mini USB)

Reset

In

FC Ports

(Loop A)

Ready

LED

2Gbps

LED

Error

LEDs

Out

In

Out

FC Ports

(Loop B)

Panel Components

RS-232 Serial Port -

Connection used for InfoStation external monitoring, RAID config-

(DB9)

uration, and control (via Hyper Terminal or Data Master).

Reset Switch -

Resets InfoStation UI (will not reset FC Loops).

RS-232 Serial Port -

Serial connection used for InfoMon external monitoring, config-

(Mini USB)

uration, and control. Mini USB-to-DB9 cable provided.

Modem Port -

Connection used for external modem.

FC Ports -

FC ports for FC-ALs. Four (4) FC ports support daisy-chaining
applications (optional).

Error LEDs -

In =

ON indicates either loop not connected, HBA error, or

(Red)

cabling problem.

Out=

ON indicates RAID Module is not ready (should turn OFF
after 15 sec).

2Gbps LED -

ON =

Indicates 2Gbps operation (factory default).

(Green)

OFF=

Indicates 1Gbps operation.

Ready LED -

ON=

Indicates RAID Module power is ready.