28

Configuration

StorCase Technology, Inc.

DS560/DS570 User's Guide - Rev. A04

19.

Press Esc and ê until the 22 Secondary Host menu is displayed, then press Enter.

20.

Repeat Steps 11-18 to select the Secondary Host.

21.

Press ê until the 5 NVRAM menu is displayed, then press Enter.

22.

Press ê until the 51 Update NVRAM menu is displayed, then press Enter.

23.

Press ê until the YES option is displayed, then press Enter.

24.

Press ê until the 53 Restart menu is displayed, then press Enter.

25.

Press ê until the YES option is displayed, then press Enter.

NOTE:

This will automatically restart the RAID Controller.

26.

Press Enter to open the 6 RAID Funcs menu.

27.

Press ê until the 62 Init R5 /R3 menu is displayed, then press Enter.

28.

Press ê until the STOP option is displayed, then press Enter.

29.

Press Esc to return to the Main Menu.

30.

Press Enter to open the 1 RAID Params menu.

31.

Press ê until the 14 Slice menu is displayed, then press Enter.

NOTE:

Slice will allow you to divide the partition size of RAID Controller.

32.

Press ê until the 141 Slice 0(MB) menu is displayed, then press Enter.

33.

Key in the desired capacity in Slice 0, then press Enter.

34.

Press ê to select the 142 Slice 1(MB) to 148 Slice 7(MB), repeat Steps 8-9.

35.

Press Esc to return to the Main Menu.

36.

Press ê until the 21 Primary SCSI menu is displayed, then press Enter.

37.

Press ê until the 216 LUN Map menu is displayed, then press Enter.

38.

Press ê until the 2161 LUN 0 menu is displayed, then press Enter.

39.

Refer to Table 5 to set-up LUN menu.

40.

Press Esc and ê until the 22 Secondary Host menu is displayed, then press Enter.

41.

Repeat Steps 36-39 to select the Secondary Host.

42.

Press Esc to return to the Main Menu.

43.

Press ê until the 5 NVRAM menu is displayed, then press Enter.

44.

Press ê until the 51 Update NVRAM menu is displayed, then press Enter.

45.

Press ê until the YES option is displayed, then press Enter.

46.

Press ê until the 53 Restart menu is displayed, then press Enter.

NOTE:

This will automatically restart the RAID Controller.

47.

Press ê until the YES option is displayed, then press Enter.

48.

Press ê until the 6 RAID Funcs menu is displayed, then press Enter.

49.

Press ê until the 62 Init R5/R3 menu is displayed, then press Enter.

50.

Press ê until the START option is displayed, then press Enter.

NOTE:

The RAID Controller is now configured for Dual Host.