beautypg.com

Configuring the raid controller, Initial raid configuration, Quick set-up – StorCase Technology DS570 User Manual

Page 33: Single host configuration

background image

24

Configuration

StorCase Technology, Inc.

DS560/DS570 User's Guide - Rev. A04

Configuring the RAID Controller

The following information describes how to configure the RAID Controller for operation. To

configure the RAID Controller, the user must first configure the RAID settings and the SCSI

settings. After these two steps are completed, the RAID Controller will be seen as a normal

SCSI disk to the host system.

Initial RAID Configuration

This section provides instructions on how to set-up a RAID configuration for the first time.

These steps may also be performed by the Monitor Utility. Refer to section "Monitor Utility"

for information on configuring and using this feature.

Quick Set-Up

1.

Make sure the RAID Controller is ON.

2.

Press Enter to display the Main Menu.

3.

Press Enter to open the 0 Quick Set-Up menu.

4.

Press ê until the 01 Quick Set-Up menu is displayed, then press Enter.

5.

Press ê until the 011 Reconfirm menu is displayed, then press Enter.

6.

Select YES to change the existing RAID configuration.

Single Host Configuration

1.

Make sure the RAID Controller is ON.

2.

Press Enter to display the Main Menu.

3.

Press Enter to open the 1 RAID Params menu.

4.

Press ê until the 11 Re-Conf RAID menu is displayed, then press Enter.

5.

Press ê until the 12 RAID Level menu is displayed, then press Enter.

6.

Select the listing "0, 1, 5" to configure for RAID Level, then press Enter.

7.

Press ê until the 13 Disk Number menu is displayed, then press Enter.

8.

Use the ê button to select the number of disks to configure for the RAID Controller,

then press Enter.

NOTE:

Disk number does not include "Hot Spare" disk.

9.

Press Esc to return to the Main Menu.

10.

Press ê until the 2 SCSI Params menu is displayed, then press Enter.

11.

Press ê until the 21 Set SCSI ID menu is displayed, then press Enter.

12.

Use the ê button to select a SCSI ID for the RAID Controller, then press Enter.

NOTE:

Default is SCSI ID 0.

13.

Press ê until the 22 Termination menu is displayed, then press Enter.

This manual is related to the following products: