Communication Parameters

Communication Parameters

Note: EOS means End of String. EOI means End or Identify.

For GPIB Communication

Terminate Read on EOS

Yes

Set EOI with EOS on Writes

Yes

Type of comparison on EOS

8-bits

EOS byte

0Ah

Sends EOI at end of Writes

Yes

GPIB primary address

10

GPIB secondary address

None

For RS-232 Communication

EOS bytes

0Ah

Baud rate

9600 bps

Parity

None

Data bits

8 bits

Stop bits

1 bits

Flow control

None

Activation

see Setting Up the Variable Attenuator for
Remote Control