beautypg.com

Band info, Data tests summary, Band info data tests summary – EXFO MaxTester DSL User Manual

Page 39

background image

MaxTester DSL

33

Band Info

The Band Info tab allows you to view a list of individual upstream or downstream
band parameter details.

³

Band contains Upstream (US) and Downstream (DS)
parameters.

³

ADSL lists only 1 of each.

³

VDSL lists US0 to 3 and DS1 to 3 possible bands,
depending on the band plan,

³

Parameter - Downstream/Upstream

³

SNR Margin is the measured current
signal-to-noise ratio margin across all active
sub-carriers, as an amount of increased noise
relative to the measured noise power that the
system would be able to tolerate. Only a value of 6
or above is able to support a bit error rate of 10

-7

.

³

Loop Attenuation is the current reduction of the
line and is measured only once during training.

³

Signal Attenuation is the current reduction of the signal and is measured
periodically when the line is connected.

³

Tx Power is the upstream/downstream transmitting power for the
selected band.

³

Output Power is the current transmit power level that is a measure of the
aggregated transmit power.

Data Tests Summary

The Data Tests Summary tab displays the pass/fail status
of the selected data tests enabled in the connection setup.
A successful WAN connection must be established in
order to view the detailed results.

To view individual data test results:
1.
Press the up/down navigation keys to select the

desired test.

2. Press

to display the test result details.