beautypg.com

Verify feedback – Delta RMC151 User Manual

Page 20

background image

RMC150 Startup Guide

Verify Feedback

1. In the Axis Status Registers

pane, on the All tab, expand the
Feedback section.

For secondary inputs, expand the
Pressure/Force/Accel Feedback
section.

2. Look at the Counts register (for analog feedback, look at Volts or

Current).
It may be changing slightly.

3. Use the Direct Output command to move the axis back and forth

(as described in the Testing an Actuator section).

4. As the axis moves, look for a corresponding change in the Counts,

Volts or Current. If it does not change smoothly, recheck the
wiring, verify that the parameters on the Setup tab are correct,
and check for smoothly changing Counts, Volts or Current again.

5. Save the project and update Flash.

18

Delta Computer Systems, Inc.

This manual is related to the following products: