Setting the common zone for multiple units, Scan for products, Controls – installation / setup / commissioning – Bonaire Touchpad User Manual
Page 48
M
ULTI
-A
PPLIANCE
T
OUCH
P
AD
Controls – Installation / Setup / Commissioning
Evaporative Air Conditioners
Step 3
The LED will now flicker a sequence of
1 through to 4 flickers with a pause in
between each set of flickers. To
allocate the unit to the correct zone,
release the reset button immediately
after the required number of flickers has
been completed. See Table.
LED
Flickers
Zone
Allocation
Unit
Identification
Code
1
ZONE 1
E01
2
ZONE 2
E02
Step 4
Move to the next unit and perform the
same procedure as in Step 2 and Step 3,
to allocate a code number to each unit.
3
ZONE 3
E03
4
ZONE 4
E04
NOTE:- Each unit must be on a separate zone. More than one unit on a zone will result in a
communication conflict causing inconsistent operation of the units.
S
ETTING THE
C
OMMON
Z
ONE
F
OR
M
ULTIPLE
U
NITS
To ensure ZONE 1 is available for use on the touchpad, the common zone must be turned off. To do this
you must enter the zone availability parameters and turn off the common zone default setting.
STEP 1 Ensure the control is in the OFF mode.
STEP 2
A series of unseen icons must be pressed
1. Press and hold the ZONE 4 (1) icon allowing
for a Triple BEEP followed by a Single BEEP.
2.
In quick succession press the unseen
APPLIANCE COOL (2) icon followed by the
HEAT (3) icon.
3.
If successfully executed the numeric area will
display tP:01.
4.
If unsuccessful repeat 1 and 2 of STEP 2.
STEP 3 Press
ENTER.
STEP 4
Using
the
arrows, for an evaporative air conditioner and select E01. Press
ENTER .
STEP 5
Press and make the ZONE 1 button solid.
STEP 6
Press FINISH
S
CAN
F
OR
P
RODUCTS
:
To access the units allocated to the zones, a forced scan must be complete with the touchpad.
STEP 1
Turn the touch pad ON
STEP 2
Turn the touch pad OFF and keep holding the
ON-OFF icon until the numeric area shows
- - - -.
STEP 3
Release the ON-OFF button and the touch
pad will scan for the new unit and re-initialise.
STEP 4
When the time clock returns to normal, turn
the touch pad on and check the units have
been successfully located to their zone.
STEP 5 Turn the zones on and check the units
function.
Bonaire Control Systems
Page 48