Auto-coding, Coding defaults, Forced scan auto-coding – Bonaire Touchpad User Manual
Page 39: Important notes, Oding, Controls – installation / setup / commissioning
M
ULTI
-A
PPLIANCE
T
OUCH
P
AD
Controls – Installation / Setup / Commissioning
Coding
A
UTO
-C
ODING
The moment the power is applied to the control system the touch pad will scan for all the new equipment
that has been installed and powered on. The powering up of a multiple configuration, a ducted central
heater and a ducted evaporative air conditioner, must happen within 20 seconds of each other for the scan
to find both units. If the scan misses one or the other units a forced scan can be done.
Important Note: Ensure all appliances are connected prior to powering up the system. Ensure also that
the remote isolation switch, where fitted, is also turned on.
If you have a ducted central heater and you are adding an evaporative air conditioner to the touch pad or
you are adding a ducted central heater to an evaporative air conditioner you can force the control to scan
for the new equipment.
C
ODING
D
EFAULTS
• Ducted Gas Central Heating
Ö
HC01 - Ducted Gas Heating and Dual Cycle Refrigerated Air Conditioning
Ö
Thermostat Mode for Heating
Ö
4 Zones ON
Ö
NO Common Zone – This can be set up subject to system design.
• Ducted Evaporative Air Conditioning
Ö
E 01 – Evaporative Air Conditioning
Ö
Thermostat Mode
F
ORCED
S
CAN
A
UTO
-C
ODING
:
To force a scan for new equipment:
1. Power up the new unit.
2. Within 3 minutes of the unit being powered up:
2.1. Turn the touch pad ON
2.2. Turn the touch pad OFF and keep holding the ON-OFF icon until the clock area shows - - - -.
Release the ON-OFF button and the touch pad will scan for the new unit and re-initialise.
3. When the time clock returns to normal, turn the touch pad on and check the unit has been coded
successfully.
4. If the unit did not code restart the process by turning the power OFF then ON at the unit to
reestablish the 3 minute coding window
I
MPORTANT
N
OTES
Things to note when connecting new products to a touch pad control
1. There is only a 3 minute coding window after the unit has been powered up to force a scan to find a
new unit.
2. Central Heating will have a default configuration that includes Dual Cycle cooling and 4 available
zones.
3. When a ducted evaporative air conditioner is added to a ducted central heater, the Dual Cycle
cooling functions are no longer available for use.
4. The auto coding process can only discriminate between a single central heater and a single
evaporative air conditioner