beautypg.com

Master hub setup and management 63 – D-Link DFE-2600 User Manual

Page 75

background image

Master Hub Setup and Management

63

SA Changes. This statistic counts the number of times the source ad-
dress has changed.

Isolates (only for 100Mbps connections). Counts the number of times
a port auto isolates.

SymbolError (only for 100Mbps connections). Counts the number of
times a received packet contained symbol errors. Only one symbol er-
ror is counted per packet regardless of the number of symbol errors
within the packet.

Total Errors. This statistic is the sum of the FCS Error, Alignment
Error, Too Long Frame, Short Event, Late Event, Very Long Event,
and Data Rate Mismatch counters.

Readable Octs. This statistic counts the total number of bytes (oc-
tets) included in valid (readable) frames.

DFE-2600 Stackable Hub - Network Monitoring : Port Statistics

Current Group ID: 1

Current Port ID: 9

Pkts

Pkts/Sec

Pkts

Pkts/Sec

Frames Too Long:

0

0

Readable Frames: 484447

0

Very Long Events:

0

0

Multicast:

7393

0

Short Events:

0

0

Broadcast:

305460

0

Late Events:

0

0

Auto Partition:

0

0

Runt Frames:

2632

0

DRM:

0

0

Collision:

8514

0

SA Changes

319965

0

FCS Errors:

395

0

Isolates:

0

0

Alignment Errors:

9

0

SymbolError:

0

0

Errs

Errs/Sec

Octs

Octs/Sec

Total Errors:

404

0

Readable Octs:

105350920

0

Next Monitoring Group ID [1]
Next Monitoring Port

ID [9 ]

PREV GROUP

NEXT GROUP

PREV PORT

NEXT PORT

CLEAR COUNTER

EXIT

You can use PREV GROUP, NEXT GROUP, PREV PORT, and NEXT
PORT
to switch hubs or ports. CLEAR COUNTER resets all counters
back to zero.