3.13 SERVICE SCHEDULE
ATTENTION: It is recommended that all service work
be performed by your nearest Generac Authorized Service Dealer.
SYSTEM/COMPONENT
PROCEDURE
FREQUENCY
X = Action
R = Replace/Adjnst as Needed
* = To Be Completed by a
Generac Authorized
Service Dealer.
Inspect
Change
Clean
D = Dally W = Weekly
M = Monthly Y = Yearly
H = Hours
FUEL
Fuel level
X
AFTER 25-H BREAK-IN,
D / BEFORE USE
Fuel lines and connections*
X
AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Füel Filter*
X
EVERY 250 H / 6 M
LUBRICATION
Oil level
X
EVERY 8 H/D
Oil
X
AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Oil filter
X
AFTER 25-H BREAK-IN,
EVERY 250 H / 6 M
Oil line leakage*
X
EVERY 100 H
COOLING
Engine cooling system*
X
AFTER 25-H BREAK-IN,
EVERY 100 H/M
Coolant level
X
AFTER 25-H BREAK-IN,
D / BEFORE USE
Coolant*
X
EVERY 500 H / Y
Enclosure louvers
X
X 1
EVERY 250 H/6 M
EXHAUST
Exhaust system
X
EVERY 100 H/M
Retorque Exhaust Manifold*
X
EVERY 750 H
Clean out MuiUer/Spark Arrestor
X
EVERY 5œH
BATTERY
Electrolyte fluid level
X
AFTER 25-H BREAK-IN, W
Charge and condition
X
R
X
W, EVERY 250 H / 6 M
FAN/ALTERNATOR BELTS
Tension and condition*
I
X
R
EVERY 7 5 0 H
ENGINE
Retorque cylinder head*
X
EVERY 750 H
Retorque intake manifold*
X
EVERY 750 H
Starter motor*
X
EVERY 750 H
Air filter
X
R
EVERY 500 H
Compression*
X
EVERY 750 H
Valve clearance*
X
R
EVERY 750 H
Governor*
X
R
EVERY 750 H
Safety devices*
X
R
EVERY 750 H
Injection system*
X
R
EVERY 750 H
GENERAL
Overall condition
X
X
AFTER 25-H BREAK-IN, W
Exercise system
W
COMPLETE TUNE-UP*
X
X
X
Y