beautypg.com

Viconics VWZS Integration Guide User Manual

Page 47

background image

47

Objects Supported By Models: (VZ7000 Zoning Products)


Please refer to the specific installation guide of each controller for a detailed overview on each property listed.

Object Name

Object Type

Object Property

VZ7

2

0

0

F

5

x

0

0

W

VZ7

2

6

0

F

5

x

0

0

W

VZ7

2

6

0

C5

x

0

0

W

VZ7

6

5

6

B1

0

0

0

W

VZ7

6

5

6

R1

0

0

0

W

VZ7

6

5

6

H1

0

0

0

W

VZ7

6

5

6

F

1

0

0

0

W

VZ7

6

5

6

E

1

0

0

0

W

Outdoor Temperature Override

Boolean Writable

Present Value (R,W)

















Occupancy Command

Enum Writable

Present Value (R,W)

















Effective Occupancy

Enum Point

Present Value (R)

















Occupied Cooling Setpoint

Numeric Writable

Present Value (R,W)

















Occupied Heating Setpoint

Numeric Writable

Present Value (R,W)

















Unoccupied Cooling Setpoint

Numeric Writable

Present Value (R,W)

















Unoccupied Heating Setpoint

Numeric Writable

Present Value (R,W)

















Temporary Occupancy Time

Enum Writable

Present Value (R,W)

















Thermostat Model Number

Numeric Point

Present Value (R)

















Module Firmware Version Number

Numeric Point

Present Value (R)

















Thermostat Firmware Version
Number

Numeric Point

Present Value (R)

















RTC Smart Recovery Active

Boolean Point

Present Value (R)

















TRSS

NumericSpecial

Present Value (R)

















CRSS

NumericSpecial

Present Value (R)

















Heartbeat Delay

NumericNoStale

Present Value (R)

















Room Temperature

Numeric Writable

Present Value (R,W)







Room Temperature Override

Boolean Writable

Present Value (R,W)







Outdoor Temperature

Numeric Writable

Present Value (R,W)







Standby Cooling Setpoint

Numeric Writable

Present Value (R,W)







Standby Heating Setpoint

Numeric Writable

Present Value (R,W)







PI Cooling Demand

Numeric Point

Present Value (R)







PI Heating Demand

Numeric Point

Present Value (R)







Weighted PI Cooling Demand

Numeric Point

Present Value (R)





