10. RESPONSE VIEW

Select [View

Response View] from the menu or press the

Frequency response indication button on the Filter, ARC, or
Xover View to show or hide the Response View.
The Response View can display the Output response and
Xover response. (The Xover Response View is displayed only
when the Xover box or its subsequent filter box is selected.)

(1)

(2)

(3)

(4) (5)

(1) Response indication selection button

Displays the types of frequency responses being currently displayed. If this button is pressed, the type of
frequency response to be displayed can be selected from the pull-down menu. There are a full-screen
display that displays any one of amplitude, phase and group delay responses, and a dual-split screen
display that displays two of these 3 responses.

(2) Scale change button

If you press this button, a dialog for scale setting is then displayed
and the graph scale of the response control can be changed.

(3) Response indication area

(4) Input selection button [Output 1 – 8]

Press this button to select either ON or OFF of response display, or input channel from the pull-down
menu.

10.1. Output Response View

• Displays an overall response from input to output.
• Permits selection of Inputs routed by matrix for each output channel.
• Permits display of 3 types of responses: amplitude, phase and group delay responses.