Delay view (delay function settings), Delay (see, P. 44 – Toa DP-K1 User Manual
Page 44
44
9.11. Delay View (Delay Function Settings)
If you click the [Delay] box, the Delay View is displayed.
(1)
(2)
(3)
(4)
(5)
(6)
(1) Minimum variation unit selection button (Increments)
Selects the minimum units of the delay time that can be changed with the Up and Down buttons.
(2) Option button
If you press this button, a delay option dialog is displayed and you
can select the unit of distance displayed on the delay distance
indication button from meters, inches and feet.
You can also set the temperature on the basis of which the delay
distance displayed is calculated.
(3) Grouping button [Grouping No.]
The group number is displayed when grouping has been set, and the "Off" indication is displayed when no
grouping has been set.
Pressing this button permits grouping to be set or cancelled.
Select either "New Group" or the number
of a group that has already been set.
Only when "New Group" has been selected,
select either "Same Value" or "Keep Offset."
Same Value: Makes gain values within the
delay time identical.
Keep Offset: Permits values to be changed
without changing the relative
delay values within the group at
the time of group setting.