beautypg.com

Toa FS-7000 SERIES Installation User Manual

Page 70

background image

70

8. REMOVABLE TERMINAL PLUG CONNECTION

Cautions
• Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and the

solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• Use cables of AWG 12 – 24.

Cable end treatment

7 mm

20 mm

2-core shielded cable

Connector connections

Step 1. Loosen the terminal screw, then insert the cable.

Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.)

1

1

2

Slotted screwdriver

Loosens

Terminal screw

Tightens

Shielded cable

Removable terminal plug

Tip
Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm in width

3 mm