[Settings]
Set the Function Switch on the FS-7000RF's rear panel to match the needs and uses of the system, as
described below.
FS-7000RF rear panel
1 2 3 4 5 6 7 8
FUNCTION SW
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
Urgency
Normal
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
2 units
3 units
4 units
Number of connected units
1 unit
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
1
8
2 3 4 5 6 7
Number of zones
Up to 10 zones
11 – 20 zones
21 – 30 zones
31 – 40 zones
41 – 50 zones
(1) FS-7000RM All-Zone Call Mode (SW#1): Normal/Urgency
(Default: Normal)
Designate the mode used to establish all-zone calls using FS-7000RM's All-Zone Call Key. If the mode is set
to "Urgency" when the FS-7000AT is connected, announcements bypass the attenuator and are allowed
through at maximum sound volume.
(2) Number of FS-7000RM units (SW #2 and #3): 1 – 4
(Default: 1)
Set the number of FS-7000RM units to be connected to the FS-7000RF.
(3) Number of system's broadcast zones (SW #4 – #6): 10/20/30/40/50
(Default: 10)
Designate the number of system's broadcast zones.
Individual zones can be selected from the FS-7000RM within a designated range of numbers. (Example: If the
number is set to 30, any number of zones from 1 to 30 can be selected, but not zones exceeding that
number.)