Ce & s, Tandard, Ersion – TeeJet ARC-6000 User Manual
Page 8
![background image](/manuals/713561/8/background.png)
ARC 6000
98-05017
Rev.- 1
1-4
CE & S
TANDARD
V
ERSION
OFF
SET- UP
DEC.
ON
OPERATE
INC.
ARC-6000
Automatic
Rate Controller
MID-TECH
MIDWEST TECHNOLOGIES, INC.
1
2
3
4
5
6
7
8
9
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
BOOMS
.
-Ac
Flow
RATE
Gal./
1
2
3
4
5
6
7
8
9
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
BOOMS
¨
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
OFF
SET- UP
ON
OPERATE
SET- UP
OPERATE
1.4.3. DISPLAY SELECTOR FUNCTIONS-OPERATE MODE (GRANULAR APPLICATION)
SPEED: The current vehicle speed in tenths of a Mile per Hour.
FIELD AREA: Accumulated Area, in hundredths of an Acre.*
TOTAL AREA: Accumulated Area, in tenths of an Acre.*
PRODUCT VOL.: Amount of product aboard the vehicle. Resets to a pre-programmed, full load by holding theINC
switch up with ground speed zero. Also allows setting any value using the INC/DEC switch. Value counts down as the
product is applied, an alarm sounds with ten percent left aboard.**
% RATE: The percent of programmed application rate at which the product is being applied. This percentage can be
changed up or down a preset amount by operating the INC/DEC switch.***
APPLICATION RATE: The desired application rate can be set with the INC/DEC switch when the ground speed is zero
or all booms are OFF.** Once application has commenced, and metered discharge is established, the actual measured
application rate will be displayed here. Also used to set the control valve to manual operation.
TOTAL APPLIED: The actual volume applied, as measured by the rate sensor. Rounds to tons after accumulating
19,999 pounds.*
IMPL. WIDTH: The active boom width in tenths of Feet. Depends on the actual boom sections selected “ON”.
DISTANCE: The accumulated distance in Feet, Miles after 5,280 Ft. (Accumulates only when selector switch is in this
position or when applying product)*
PRIME: This position is used to lock the control valve open. It can be used in a granular application to unload the
vehicle at its maximum discharge rate. Initially the display will show a series of five dashes. Hold INC switch up for
three seconds to lock the control valve fully open. The display will read OPEN. Switching away or toggling the DEC
switch will cause the valve to CLOSE.
TEST SPEED: The speed the console will use for stationary tests of the sprayer. Use the INC/DEC switch to change this
value.**
SCAN: The display will scan SPEED, FIELD AREA, PRODUCT VOLUME, APPLICATION RATE and TOTAL
APPLIED. The display will hold at each position for approximately two seconds before automatically cycling to the
next.
NOTES: * Totals can be zeroed in this mode.
** Values are programmable in this mode.
***Values changeable by a % increase or decrease.