Ce & s, Tandard, Ersion – TeeJet ARC-6000 User Manual

Page 8

background image

ARC 6000

98-05017

Rev.- 1

1-4

CE & S

TANDARD

V

ERSION

OFF

SET- UP

DEC.

ON

OPERATE

INC.

ARC-6000

Automatic

Rate Controller

MID-TECH

MIDWEST TECHNOLOGIES, INC.

1

2

3

4

5

6

7

8

9

%Rate

DISPLAY SELECTOR

Speed

Field Area

Impl.Width

Distance

Test

Speed

Prime

Total Applied

Application Rate

Scan

Total Area

Product Vol.

BOOMS

.

-Ac

Flow

RATE

Gal./

1

2

3

4

5

6

7

8

9

%Rate

DISPLAY SELECTOR

Speed

Field Area

Impl.Width

Distance

Test

Speed

Prime

Total Applied

Application Rate

Scan

Total Area

Product Vol.

BOOMS

¨

%Rate

DISPLAY SELECTOR

Speed

Field Area

Impl.Width

Distance

Test

Speed

Prime

Total Applied

Application Rate

Scan

Total Area

Product Vol.

OFF

SET- UP

ON

OPERATE

SET- UP

OPERATE

1.4.3. DISPLAY SELECTOR FUNCTIONS-OPERATE MODE (GRANULAR APPLICATION)

SPEED: The current vehicle speed in tenths of a Mile per Hour.

FIELD AREA: Accumulated Area, in hundredths of an Acre.*

TOTAL AREA: Accumulated Area, in tenths of an Acre.*

PRODUCT VOL.: Amount of product aboard the vehicle. Resets to a pre-programmed, full load by holding theINC

switch up with ground speed zero. Also allows setting any value using the INC/DEC switch. Value counts down as the
product is applied, an alarm sounds with ten percent left aboard.**

% RATE: The percent of programmed application rate at which the product is being applied. This percentage can be

changed up or down a preset amount by operating the INC/DEC switch.***

APPLICATION RATE: The desired application rate can be set with the INC/DEC switch when the ground speed is zero

or all booms are OFF.** Once application has commenced, and metered discharge is established, the actual measured
application rate will be displayed here. Also used to set the control valve to manual operation.

TOTAL APPLIED: The actual volume applied, as measured by the rate sensor. Rounds to tons after accumulating

19,999 pounds.*

IMPL. WIDTH: The active boom width in tenths of Feet. Depends on the actual boom sections selected “ON”.

DISTANCE: The accumulated distance in Feet, Miles after 5,280 Ft. (Accumulates only when selector switch is in this

position or when applying product)*

PRIME: This position is used to lock the control valve open. It can be used in a granular application to unload the

vehicle at its maximum discharge rate. Initially the display will show a series of five dashes. Hold INC switch up for
three seconds to lock the control valve fully open. The display will read OPEN. Switching away or toggling the DEC
switch will cause the valve to CLOSE.

TEST SPEED: The speed the console will use for stationary tests of the sprayer. Use the INC/DEC switch to change this

value.**

SCAN: The display will scan SPEED, FIELD AREA, PRODUCT VOLUME, APPLICATION RATE and TOTAL

APPLIED. The display will hold at each position for approximately two seconds before automatically cycling to the
next.

NOTES: * Totals can be zeroed in this mode.

** Values are programmable in this mode.
***Values changeable by a % increase or decrease.